Published May 1990 | Version v1
Journal article

The preparation and clinical application of 99mTc-HSA instant kit

  • 1. West China Univ. of Medical Science, Chengdu, SC (China). First Affiliated Hospital

Description

The preparation and preliminary clinical application of 99mTc-HSA instant kit are reported. The data show that the radiochemical purity of 99mTc-HSA prepared by the method discribed is > 97%. Its stability is excellent in vitro and it can be left at room temperature for more than 2 hours. The T1/2 for disappearance of radio activity from the blood was 243 minutes. Sn-HSA kits can be stored at 2 ∼ 4 deg C for 3 months. By the use of 99mTc-HSA, the liver blood pool imaging and the gated cardiac blood pool imaging were performed satisfactoryly in 30 and 102 cases respectively. No toxic effects were observed in the patients examined. The authors are of the opinion that 99mTc-HSA prepared by the method is a successful agent for various blood pool imaging and is suitable for routine use

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Medicine
Journal Volume
10
Journal Issue
2
Series
Chin. J. Nucl. Med.
Journal Page Range
81-83
ISSN
0253-9780
CODEN
CITCD