Published November 2014 | Version v1
Journal article

Observation of critical heat flux mechanism in horizontal pool boiling of saturated water

  • 1. Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 303-353 (Korea, Republic of)
  • 2. Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 335 Gwahak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

Description

Highlights: • A large dry patch is formed under a coalesced massive bubble. • A residual dry patch is produced at the departure of the coalesced massive bubble. • The residual dry patch expands to larger one due to enhanced nucleation activity. • Continuous re-expansion of the residual dry patch triggers the boiling crisis. - Abstract: We observed the global boiling structure and dynamic behavior of dry areas in a synchronized manner to identify the critical heat flux (CHF) triggering mechanism in a horizontal pool boiling of saturated water. A transparent Indium Tin Oxide (ITO) heating surface was used to accommodate a total reflection technique. The total reflection images captured the detailed processes of the generation of discrete dry spots, the formation and rewetting of large dry patches, and the irreversible expansion of the dry patch which led to the occurrence of the CHF. Contrary to the common postulation that a thin liquid film exists stably under a coalesced massive bubble, the base of hovering massive bubbles was almost dry at more than 10% below the CHF condition. The key element that determines the occurrence of the CHF was the production of the residual dry patch and consecutive re-expansion of the residual dry patch owing to the enhanced bubble nucleation activity with an increase in wall superheat, rather than the complete dryness of a boiling surface under a hovering massive bubble. The dry area fraction of the present water boiling test was similar to that of the R-113 boiling test in the literature in spite of significant differences in the wettability and physical properties

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nucengdes.2014.03.013

Additional details

Identifiers

DOI
10.1016/j.nucengdes.2014.03.013;
PII
S0029-5493(14)00160-5;

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
279
Journal Page Range
p. 189-199
ISSN
0029-5493
CODEN
NEDEAU

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46100764
Subject category
S42: ENGINEERING;
Descriptors DEI
BUBBLES; CRITICAL HEAT FLUX; EXPANSION; HEATING; IMAGES; LIQUIDS; NUCLEATION; PHYSICAL PROPERTIES; POOL BOILING; REFLECTION; REWETTING; TIN OXIDES; WALLS; WATER; WETTABILITY
Descriptors DEC
BOILING; CHALCOGENIDES; FLUIDS; HEAT FLUX; HYDROGEN COMPOUNDS; OXIDES; OXYGEN COMPOUNDS; PHASE TRANSFORMATIONS; TIN COMPOUNDS

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.