Published 1979 | Version v1
Report Open

Ionization measuring on automatic processing images from a bubble chamber

Description

A method for measuring the ionization by the density of particle tracks on pictures of hydrogen events chamber is described. The track point file obtained by scanning a picture by the PSP-2 automatic device is initial data for measuring the density. Programs realizing this measuring method are incorporated into the filtering cycle and are employed in the ES-1010 and BESM-6 computers. Comparison of the accuracy of ionization measurements performed by an operator and the automatic device shows that in the range of proton momenta from 0.5 to 2 GeV/c the automatic device is not inferior to a skilled operator. Errors of the visible ionization calculated value in this range do not exceed 20%

Availability note (English)

MF available from INIS under the Report Number.

Files

12582349.pdf

Files (215.9 kB)

Name Size Download all
md5:3bb9ba1a13cdf7b4745d76c932d630b6
215.9 kB Preview Download

System files (20.5 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Измерение ионизации в автоматической обработке снимков пузырьковой камеры

Publishing Information

Imprint Pagination
10 p.
Report number
ITEF--106(1979)

Optional Information

Notes
4 refs.; 1 fig.