Measurement of contact resistance and heat load test on graphite limiter
- 1. Mitsubishi Atomic Power Industries, Inc., Tokyo (Japan)
Description
A simple graphite limiter has been designed for high heat load in a tokamak device. The thermal contact conductance αsub(c) was measured as the function of contacting pressure p, because αsub(c) is an important parameter for the graphite limiter design. Both experiments on small samples and full scale limiter assembly provided consistent data of αsub(c) = -- 0.1 W/cm2.0C at p = 1 kgf/cm2 (-- 0.1 MPa). This value is considered to be sufficiently large from the viewpoint of the limiter thermal design. Heat load test was performed on the simple graphite limiter by using electron beam. Two kinds of materials employed in the test were POCO graphite and SIC-6 graphite which has thermal expansion coefficient similar to that of SiC. The test results showed that both graphite materials had enough thermal shock resistance to the heat load q = -- 500 W/cm2, t = 3 -- 20 s, and SiC coating on SIC-6 graphite had better behavior against thermal shock, comparing with TiC coating on POCO graphite. (author)
Additional details
Publishing Information
- Journal Title
- J. Nucl. Sci. Technol. (Tokyo)
- Journal Volume
- 22
- Journal Issue
- 7
- Series
- J. Nucl. Sci. Technol. (Tokyo).
- Journal Page Range
- 529-537
- ISSN
- 0022-3131
- CODEN
- JNSTA
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 17063893
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ELECTRON BEAMS; GRAPHITE; LIMITERS; THERMAL CONDUCTION; THERMAL CONDUCTIVITY; THERMAL SHOCK; THERMAL TESTING; TOKAMAK DEVICES
- Descriptors DEC
- BEAMS; CARBON; CLOSED PLASMA DEVICES; ELEMENTS; ENERGY TRANSFER; HEAT TRANSFER; LEPTON BEAMS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; NONMETALS; PARTICLE BEAMS; PHYSICAL PROPERTIES; TESTING; THERMODYNAMIC PROPERTIES; THERMONUCLEAR DEVICES