Published May 16, 2005 | Version v1
Report

MEASUREMENT AND CORRECTION OF NONLINEAR CHROMATICITY IN RHIC

Description

To improve luminosity in RHIC by using smaller β*, higher order chromatic effects may need to be corrected [1]. Measuring of higher order chromaticities is discussed and compared to a model of RHIC, showing agreement. Assuming round beams, four families of octupoles are used to correct the second order chromaticities while keeping under control the amplitude dependent betatron tune spread in the beams. We show that the octupoles can reduce the second order chromaticity in RHIC, but they have insufficient strength for complete correction

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/15016130-cwIuXW/native/

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
BNL--73491-2005-CP

Conference

Title
PAC 2005
Dates
16-20 May 2005
Place
Knoxville, TN (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
36055446
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
AMPLITUDES; BEAM EMITTANCE; BETATRONS; BROOKHAVEN RHIC; LUMINOSITY; OCTUPOLES
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; HEAVY ION ACCELERATORS; MULTIPOLES; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; STORAGE RINGS

Optional Information

Contract/Grant/Project number
KB--0202011; AC--02-98CH10886
Funding organization
DOE/SC (United States)