Published May 16, 2005
| Version v1
Report
MEASUREMENT AND CORRECTION OF NONLINEAR CHROMATICITY IN RHIC
Description
To improve luminosity in RHIC by using smaller β*, higher order chromatic effects may need to be corrected [1]. Measuring of higher order chromaticities is discussed and compared to a model of RHIC, showing agreement. Assuming round beams, four families of octupoles are used to correct the second order chromaticities while keeping under control the amplitude dependent betatron tune spread in the beams. We show that the octupoles can reduce the second order chromaticity in RHIC, but they have insufficient strength for complete correction
Availability note (English)
Available from PURL: https://www.osti.gov/servlets/purl/15016130-cwIuXW/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- BNL--73491-2005-CP
Conference
- Title
- PAC 2005
- Dates
- 16-20 May 2005
- Place
- Knoxville, TN (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 36055446
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AMPLITUDES; BEAM EMITTANCE; BETATRONS; BROOKHAVEN RHIC; LUMINOSITY; OCTUPOLES
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; HEAVY ION ACCELERATORS; MULTIPOLES; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; STORAGE RINGS
Optional Information
- Contract/Grant/Project number
- KB--0202011; AC--02-98CH10886
- Funding organization
- DOE/SC (United States)