Corrosion and protection of uranium alloy penetrators
Description
Penetrators made from either a U--3/4 percent Ti alloy or a U--3/4 percent Mo--3/4 percent Zr--3/4 percent Nb--1/2 percent Ti alloy (''Quad'') corrode mildly in moist air, significantly in moist nitrogen, and severely in salt fog. Adequate protection was provided in moist air and nitrogen by coating with electroplated nickel, electroplated nickel and zinc with a chromate finish, and galvanized zinc with a chromate finish. In salt fog, electroplated nickel offered only temporary protection whereas galvanized zinc and electroplated nickel-zinc provided long-lasting protection. The resistance of uncoated penetrators was affected variously by dissimilar metal couplings. Aluminum protected the Quad alloy and adversely affected the U--3/4 percent Ti alloy, whereas steel enhanced localized corrosion in both. (U.S.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Augmented title (English)
- U--3/4 percent Ti; U--3/4 percent Mo--3/4 percent Nb--3/4 percent Zr--1/2 percent Ti
Publishing Information
- Imprint Pagination
- 96 p.
- Report number
- SAND--75-8243
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 6209175
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- AIR; CORROSION; HUMIDITY; MOLYBDENUM ADDITIONS; NICKEL; NIOBIUM ADDITIONS; NITROGEN; PROTECTIVE COATINGS; SODIUM CHLORIDES; TITANIUM ADDITIONS; URANIUM BASE ALLOYS; ZINC; ZIRCONIUM ADDITIONS
- Descriptors DEC
- ACTINIDE ALLOYS; ALKALI METAL COMPOUNDS; ALLOYS; CHEMICAL REACTIONS; CHLORIDES; CHLORINE COMPOUNDS; COATINGS; ELEMENTS; FLUIDS; GASES; HALIDES; HALOGEN COMPOUNDS; METALS; NONMETALS; SODIUM COMPOUNDS; TRANSITION ELEMENTS; URANIUM ALLOYS