Published March 2, 1995 | Version v1
Report Open

Analysis of the flexible receiver lifting yoke and blast shield assembly. Tank 241SY101

Description

The analysis of the lifting yoke and blast shield assembly considers the bending stress, weld strength, and resistance of the lug hole to tear out. The bending stress of the lifting lugs is evaluated to ensure that they meet the requirements of the American Institute for Steel Construction (AISC 1989). Also considered in the calculations is the capability of the thick lugs to withstand the weight of the pump together with that of the container and strongback during rotation to the horizontal position

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95008477; NTIS; US Govt. Printing Office Dep.

Files

26055090.pdf

Files (952.8 kB)

Name Size Download all
md5:4087f83be3b094eb25bc7b172d5dd56a
952.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
31 p.
Report number
WHC-SD--WM-DA-160

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).