Published 1980
| Version v1
Report
Open
System for experiments with neutron diffractometer by the time-of-flight method based on the SM-3 and external memory of the SM-3101 computers
Description
A data acquisition and processing system for experiments on the neutron diffractometer by the time-of-flight method is described. The system is based on the SM-3 minicomputer linked with the external memory device of SM-3101 type of 32 K capacity. The software has been created using the SANPO system means
Availability note (English)
MF available from INIS under the Report Number.Files
13648530.pdf
Files
(169.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:3a11d4b4b77b7c48877b7dce42f8f12f
|
169.6 kB | Preview Download |
System files
(23.3 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Система на базе EhVM SM-3 и внешней памяти SM-3101 для экспериментов с нейтронным дифрактометром по методу времени пролета
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- JINR-R--10-80-824
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 13648530
- Subject category
- S99: GENERAL AND MISCELLANEOUS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COMPUTER CODES; DATA ACQUISITION SYSTEMS; DATA PROCESSING; FLOWSHEETS; MEMORY DEVICES; MICROPROCESSORS; NEUTRON DIFFRACTOMETERS; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- DIAGRAMS; DIFFRACTOMETERS; ELECTRONIC CIRCUITS; INFORMATION; MEASURING INSTRUMENTS; MICROELECTRONIC CIRCUITS
Optional Information
- Notes
- 9 refs.; 3 figs.