Published 1996 | Version v1
Book

Performance of CVD diamond microstrip detectors under particle irradiation

  • 1. Ohio State Univ., Columbus, OH (United States)

Description

The inherent properties of diamond make it an ideal material for detectors in the high rate, high radiation environments near the collision point of future colliders such as the LHC. We have constructed charged particle position sensitive detectors using high quality Chemical Vapour Deposited (CVD) diamond. Using detectors with a 50 pm strip pitch, we achieved a most probable signal-to-noise ratio of 27/1 and a position resolution of 12-15 pm. To ascertain the radiation hardness properties of CVD diamond, we have exposed detectors to 10 MRad 60Co, 5 x 1014 300 MeV pions/cm2, 1014 500 MeV protons/cm2, and 1015 neutrons/cm2. The results show that CVD diamond is an extremely radiation hard material and well suited for particle detector production

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (United States)
Imprint Title
1996 IEEE nuclear science symposium - conference record. Volumes 1, 2 and 3
Imprint Pagination
2138 p.
Journal Page Range
p. 205-208.

Conference

Title
Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference.
Dates
2-9 Nov 1996.
Place
Anaheim, CA (United States).

Optional Information

Secondary number(s)
CONF-961123--.