Published November 1994 | Version v1
Report Open

Measurements of TFTR D-T radiation shielding efficiency

  • 1. Princeton Plasma Physics Lab., NJ (United States)
  • 2. U.S. DOE Environmental Measurements Lab., New York, NY (United States)

Description

Measurements of neutron and gamma dose-equivalents were performed in the Test Cell, at the outer Test Cell wall, in nearby work areas, and out to the nearest property lines at a distance of 180 m. Argon ionization chambers, moderated 3He proportional counters, and fission chamber detectors were used to obtain measurements of neutron and gamma dose-equivalents per D-T neutron during individual TFTR discharges. These measured neutron and gamma D-T dose-equivalents per TFTR neutron characterize the effects of local variations in material density resulting from the complex asymmetric site geometry. The measured dose-equivalents per TFTR D-T neutron and the cumulative neutron production were used to determine that the planned annual TFTR neutron production of 1 x 1021 D-T neutrons is consistent with the design objective of limiting the total dose-equivalent at the property line, from all radiation sources and pathways, to less than 10 mrem per year

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95003581; NTIS; US Govt. Printing Office Dep.

Files

26033013.pdf

Files (566.8 kB)

Name Size Download all
md5:fcca541c9fb38d6ee5050db2a52abfb0
566.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
26 p.
Report number
PPPL--3020

Optional Information

Contract/Grant/Project number
Contract AC02-76CH03073
Funding organization
USDOE, Washington, DC (United States).