Published March 1994 | Version v1
Journal article

Nonionic contrast media in pediatric CT. A comparative study of intravenous use of iopentol and iohexol

  • 1. Nycomed AB, Lidingoe (Sweden)
  • 2. Dept. of Pediatric Radiology, Oestra Hospital, Goeteborg (Sweden)

Description

In this pediatric CT trial, the safety, tolerability and efficacy of 2 nonionic contrast media, iopentol (Imagopaque) and iohexol (Omnipaque), were evaluated. The study was performed as a double-blind, randomized, parallel trial, with 55 children receiving iopentol (300 mg I/ml) and 55 receiving iohexol (300 mg I/ml). The dose injected was 2 ml/kg b.w. with an upper limit of 100 ml. Blood pressure and pulse rate were recorded. Adverse events were recorded by observation of the patients up to 24 hours after the examination. No clinically or statistically significant changes occurred. Seven adverse events other than discomfort (2 in the iopentol group and 5 in the iohexol group) were reported. The overall quality of CT enhancement was good or excellent in all cases. (orig./MG)

Additional details

Publishing Information

Journal Title
Acta Radiologica
Journal Volume
35
Journal Issue
2
Journal Page Range
p. 186-190.
ISSN
0284-1851
CODEN
ACRAE3

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
26001372
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHILDREN; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DIAGNOSTIC USES; IOHEXOL; PEDIATRICS; SIDE EFFECTS
Descriptors DEC
ANIMALS; EVALUATION; MAMMALS; MAN; MEDICINE; PRIMATES; TOMOGRAPHY; USES; VERTEBRATES