Published May 2007 | Version v1
Journal article

Check of the 2005-look up table for prediction of CHF in bundles

  • 1. AREVA NP, NEPR-G, P.O. Box 3220, D-91058 Erlangen (Germany)

Description

The check whether it is possible to use the 2005-look up table primary designed for heated pipes also for heated rod bundles gives the surprising result that the bundle critical power for five data sets of three different bundles and different power distributions are predicted by a simple method described above using the 2005-look up table within the accuracy reported by the authors of this table

Additional details

Identifiers

DOI
10.1016/j.nucengdes.2006.10.021;
PII
S0029-5493(06)00621-2;

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
237
Journal Issue
9
Journal Page Range
p. 978-981
ISSN
0029-5493
CODEN
NEDEAU

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38090201
Subject category
S42: ENGINEERING;
Descriptors DEI
ACCURACY; FORECASTING; FUEL ELEMENT CLUSTERS; PIPES; POWER DISTRIBUTION
Descriptors DEC
FUEL ASSEMBLIES; TUBES

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.