A comparison of clonogenic and radionuclide uptake assays for determining the radiation response of human small-cell lung cancer xenografts and cell lines

  • 1. Medical Research Council, Cambridge (UK)

Description

The response of eight cell lines to a single dose of 2 Gy was measured using both radionuclide uptake and clonogenic assays. There was no correlation between the two sets of data. Agreement between the radiation-response curves obtained using 3HTdR uptake and clonogenic assays was better for high plating efficiency xenografts (NCI-H69, COR-L51) than for low plating efficiency xenografts (COR-L24, COR-L31). Radionuclide uptake indicated very shallow response curves for the low plating efficiency lines. Altering the time of radionuclide addition from the standard Day 4 to other times between Day 2 and Day 6 did not greatly change the indications of radioresponsiveness provided by the assay. Growth-curve experiments for line COR-L24 showed that cell numbers at Day 4 after irradiation with 1.5 Gy or 3 Gy were very similar to those in unirradiated cultures. For NCI-H69, however, cell numbers were very different for the different radiation doses. It appears that a high proportion of cells in lines such as COR-L24 take many days to show radiation damage as measured by reduced 3HTdR uptake. (author)

Additional details

Publishing Information

Journal Title
Br. J. Radiol.
Journal Volume
60
Journal Issue
712
Series
Br. J. Radiol.
Journal Page Range
381-388
ISSN
0007-1285
CODEN
BJRAA