Published November 2008
| Version v1
Journal article
Lower limit of determination values for trace elements in iron certified reference materials by neutron activation analysis with multiple gamma-ray detection
Creators
- 1. Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan). Nuclear Science and Engineering Directorate
Description
Recycling steel products demands a new technique for determining tramp elements in steel. Tramp elements, As and Sb, in some iron certified reference materials were determined by neutron activation analysis with multiple gamma-ray detection method and reported in MTAA11. In MTAA12, the authors reported the lower limit of determination values (LDL) and the dispersion of this method. The values of the LDLs for As and Sb in high purity iron were 0.002 and 0.0009 μg x g-1. The dispersion is small enough to satisfy the demand from materials science. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 278
- Journal Issue
- 2
- Journal Page Range
- p. 521-525
- ISSN
- 0236-5731
- CODEN
- JRNCDM
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 40031916
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S36: MATERIALS SCIENCE;
- Descriptors DEI
- ANTIMONY; ARSENIC; GAMMA SPECTROSCOPY; IRON; METAL INDUSTRY; NEUTRON ACTIVATION ANALYSIS; RECYCLING; TRACE AMOUNTS
- Descriptors DEC
- ACTIVATION ANALYSIS; CHEMICAL ANALYSIS; ELEMENTS; INDUSTRY; METALS; NONDESTRUCTIVE ANALYSIS; SEMIMETALS; SPECTROSCOPY; TRANSITION ELEMENTS
Optional Information
- Notes
- 7 refs.