Published November 2008 | Version v1
Journal article

Lower limit of determination values for trace elements in iron certified reference materials by neutron activation analysis with multiple gamma-ray detection

  • 1. Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan). Nuclear Science and Engineering Directorate

Description

Recycling steel products demands a new technique for determining tramp elements in steel. Tramp elements, As and Sb, in some iron certified reference materials were determined by neutron activation analysis with multiple gamma-ray detection method and reported in MTAA11. In MTAA12, the authors reported the lower limit of determination values (LDL) and the dispersion of this method. The values of the LDLs for As and Sb in high purity iron were 0.002 and 0.0009 μg x g-1. The dispersion is small enough to satisfy the demand from materials science. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
278
Journal Issue
2
Journal Page Range
p. 521-525
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
7 refs.