Published May 1982 | Version v1
Journal article

Microprocessor-controlled phase analysis for a 2-mm microwave interferometer on the TCA tokamak

  • 1. Centre de Recherches en Physique des Plasmas, Association Euratom--Confederation Suisse, Ecole Polytechnique Federale de Lausanne, CH-1007 Lausanne, Switzerland

Description

The method of phase analysis is presented for a 2-mm microwave interferometer built to measure the plasma density in a tokamak. Use is made of a fast phase shifter (FPS) constructed from a switchable four-port circulator to resolve the phase ambiguity inherent in a simple interferometer. The phase between 0--2π is calculated by a microprocessor accessing a look-up table and the total phase is calculated by taking the 0 to 2π crossings into consideration. It is software controlled and the complete sampling and analysis cycle takes 24 μs which is sufficiently rapid for the application considered. The phase information is available in analog and digital form

Additional details

Publishing Information

Journal Title
Rev. Sci. Instrum.
Journal Volume
53
Journal Issue
5
Series
Rev. Sci. Instrum.
Journal Page Range
600-605
ISSN