Published February 2000 | Version v1
Report

Clean environment of cavity assembly and the cavity performance

  • 1. High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

Description

To see cavity assembly environment effect on the performance, a L-band niobium cavity with cavity performance: Qo ∼ 3x1010 and Eacc,max=29 MV/m was disassembled and subsequently reassembled in the various clean areas. As a result it was made clear that the cleanliness of real class 100 is required to keep the high cavity performance. (author)

Part of:
Proceedings of the 2nd superconducting linear accelerator meeting in Japan

Additional details

Publishing Information

Imprint Title
Proceedings of the 2nd superconducting linear accelerator meeting in Japan
Imprint Pagination
209 p.
Journal Page Range
p. 97-100
Report number
KEK-PROC--99-25

Conference

Title
2. superconducting linear accelerator meeting in Japan
Dates
27-28 May 1999
Place
Tsukuba, Ibaraki (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
32010659
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATION; ACCELERATORS; AIR CLEANING; ENVIRONMENTAL QUALITY; FABRICATION; NIOBIUM; PERFORMANCE; PURIFICATION; RF SYSTEMS; SUPERCONDUCTING CAVITY RESONATORS
Descriptors DEC
ALLOYS; CAVITY RESONATORS; CLEANING; ELECTRONIC EQUIPMENT; ELEMENTS; EQUIPMENT; METALS; REFRACTORY METALS; RESONATORS; SUPERCONDUCTING DEVICES; TRANSITION ELEMENTS

Optional Information

Notes
1 ref., 5 figs., 2 tabs.