Size-affected single-slip behavior of René N5 microcrystals

  • 1. Air Force Research Laboratory, Materials and Manufacturing Directorate, 2230 10th Street, Wright-Patterson AFB, OH 45433 (United States)
  • 2. Department of Materials Science and Engineering, Ohio State University, 477 Watts Hall, 2041 College Road, Columbus, OH 43210 (United States)
  • 3. UES Inc., 4401 Dayton-Xenia Road, Dayton, OH 45432 (United States)

Description

Highlights: ► Microcompression testing was conducted on the single crystal superalloy René N5. ► All microcrystals exhibited size-affected plastic flow. ► Dendrite core microcrystals were stronger than those from interdendritic regions. - Abstract: Microcompression testing was conducted on the cast single crystal nickel-base superalloy René N5. Microcrystals were selectively fabricated from either dendrite core or interdendritic regions. The compression axis was oriented for single-slip deformation and microcrystal diameters ranged from 2.5 to 80 μm. All microcrystals displayed several hallmarks of size-affected plastic flow, including a size-affected and stochastic flow-stress and initial strain hardening rate, as well as an intermittent flow response. The magnitude of size-affected flow-stress scaling behavior was dependent upon the plastic strain level of the flow-stress measurement, with increasing size-dependence for increasing strain levels. TEM analysis demonstrated the activation of multiple slip-systems, despite the microcrystals being oriented for single-slip deformation. Zig-zag slip was also observed in microcrystals that achieved flow stresses of ∼1300 MPa or higher. For microcrystals fabricated within interdendritic regions the flow-stress values are, on average, lower compared to dendrite core microcrystals. This difference in flow-stress is especially pronounced for microcrystals which are 5 μm in diameter. The microcrystal diameter for which bulk-like properties are estimated to be observed is approximately 350 μm, which is approaching the measured primary dendrite arm spacing for this crystal (430 μm).

Availability note (English)

Available from http://dx.doi.org/10.1016/j.msea.2011.12.041

Additional details

Identifiers

DOI
10.1016/j.msea.2011.12.041;
PII
S0921-5093(11)01422-5;

Publishing Information

Journal Title
Materials Science and Engineering. A, Structural Materials: Properties, Microstructure and Processing
Journal Volume
535
Journal Page Range
p. 53-61
ISSN
0921-5093
CODEN
MSAPE3