Published November 1993 | Version v1
Journal article

Smolensk gets GOMIS

  • 1. Torness Power Station, Dunbar (United Kingdom)
  • 2. Scottish Nuclear Ltd., Glasgow (United Kingdom)

Description

Improving safety at the Soviet designed RBMK reactors is not simply a matter of backfits. Effective management information systems and maintenance schedules will be needed, and not just for increased safety. A computer-based maintenance management information system is described, called GOMIS as are the introduction of various Nondestructive Testing programs. (Author)

Additional details

Publishing Information

Journal Title
Atom (London)
Journal Issue
no.431
Journal Page Range
p. 28-29.
ISSN
0004-7015
CODEN
ATMMAR