There is a newer version of the record available.

Published September 2021 | Version v1
Journal article

Margin calculation for multiple lung metastases treated with single-isocenter SBRT

  • 1. Department of Radiation Oncology, University Hospital Zürich and University of Zürich (Switzerland)
  • 2. Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy (Netherlands)

Description

Highlights: • Safety margin calculation for single-isocenter SBRT of multiple lung metastases. • Relative inter-lesion motion is compensated by an additional 1 mm margin. • Pleural attachment is characterized with reduced inter-lesion position variation. • For 65% dose prescriptions, random errors contribute to the margin only in SI. A single-isocenter stereotactic body radiotherapy (SBRT) approach for multiple lung metastases has the potential to lower cumulative patient dose and reduce overall treatment time. However, the magnitude of inter-lesion position variation is currently unknown and not incorporated in margin calculations. The aim of this study was to quantify inter-lesion position variation and calculate safety margins for single-isocenter lung SBRT.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2021.07.001

Additional details

Identifiers

DOI
10.1016/j.radonc.2021.07.001;
PII
S0167814021066275;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
162
Journal Page Range
p. 105-111
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
54014094
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DOSES; ERRORS; LUNGS; METASTASES; NEOPLASMS; PATIENTS; RADIOTHERAPY; SAFETY MARGINS
Descriptors DEC
BODY; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright
Copyright (c) 2021 The Authors. Published by Elsevier B.V.