Published October 1993 | Version v1
Journal article

Mathematical model and analysis of micro-hydrogen detection system

  • 1. Qinghua Univ., Beijing (China). Dept. of Thermal Engineering

Description

According to the physical process of the micro-hydrogen detection system used for leak diagnosis in LMFBR steam generator, a complete mathematical model is established, which includes nickel senor, vacuum pump and the connective tube between them. The properties of the detection system have been entirely analyzed on the basis of the model. The design principle (standard, criterion) of the system has been proposed

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
14
Journal Issue
5
Journal Page Range
p. 440-444.
ISSN
0258-0926
CODEN
HDGOE6