Guidelines for confirmatory inplant tests of safety-relief valve discharges for BWR plants
Description
Inplant tests of safety/relief valve (SRV) discharges may be required to confirm generically established specifications for SRV loads and the maximum suppression pool temperature, and to evaluate possible effects of plant-unique parameters. These tests are required in those plants which have features that differ substantially from those previously tested. Guidelines for formulating appropriate test matrices, establishing test procedures, selecting necessary instrumentation, and reporting the test results are provided in this report. Guidelines to determine if inplant tests are required on the basis of the plant unique parameters are also included in the report
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 23 p.
- Report number
- NUREG--0763
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13675794
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BWR TYPE REACTORS; PERFORMANCE TESTING; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; FLOW REGULATORS; REACTORS; TESTING; WATER COOLED REACTORS; WATER MODERATED REACTORS