Published May 1981 | Version v1
Report Restricted

Guidelines for confirmatory inplant tests of safety-relief valve discharges for BWR plants

Description

Inplant tests of safety/relief valve (SRV) discharges may be required to confirm generically established specifications for SRV loads and the maximum suppression pool temperature, and to evaluate possible effects of plant-unique parameters. These tests are required in those plants which have features that differ substantially from those previously tested. Guidelines for formulating appropriate test matrices, establishing test procedures, selecting necessary instrumentation, and reporting the test results are provided in this report. Guidelines to determine if inplant tests are required on the basis of the plant unique parameters are also included in the report

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
23 p.
Report number
NUREG--0763

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
13675794
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
BWR TYPE REACTORS; PERFORMANCE TESTING; VALVES
Descriptors DEC
CONTROL EQUIPMENT; FLOW REGULATORS; REACTORS; TESTING; WATER COOLED REACTORS; WATER MODERATED REACTORS