Published May 1993 | Version v1
Report Open

A camera for imaging hard x-rays from suprathermal electrons during lower hybrid current drive on PBX-M

  • 1. Princeton Univ., NJ (United States). Plasma Physics Lab.
  • 2. Massachusetts Inst. of Tech., Cambridge, MA (United States). Plasma Fusion Center
  • 3. Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics
  • 4. JET Joint Undertaking, Abingdon (United Kingdom)

Description

During lower hybrid current drive (LHCD), suprathermal electrons are generated that emit hard X-ray bremsstrahlung. A pinhole camera has been installed on the PBX-M tokamak that records 128 x 128 pixel images of the bremsstrahlung with a 3 ms time resolution. This camera has identified hollow radiation profiles on PBX-M, indicating off-axis current drive. The detector is a 9in. dia. intensifier. A detailed account of the construction of the Hard X-ray Camera, its operation, and its performance is given

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE93014599; NTIS; US Govt. Printing Office Dep.

Files

25013111.pdf

Files (1.0 MB)

Name Size Download all
md5:f31833aa0d8cb34332b21e4a7abeadba
1.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
34 p.
Report number
PPPL--2909

Optional Information

Contract/Grant/Project number
Contract AC02-76CH03073
Funding organization
USDOE, Washington, DC (United States).