Published March 2019 | Version v1
Journal article

Development of clearance verification equipment for uranium-bearing waste

  • 1. Ningyo-toge Environmental Engineering Center, Japan Atomic Energy Agency (Japan)

Description

Highlights: • A model to reduce uncertainty of quantitative determination of uranium content in a drum is applied. • The 1.001 MeV gamma rays emitted by 234mPa (a short-lived member of the 238U decay-series) and the associated scattered gamma rays were used in this model. • Relative errors between the quantitative values of uranium amounts and the true values were almost within ±25%, for as little as 0.5 g. - Abstract: Dismantled materials generated from nuclear facilities are reused or directed to repository sites. If scrap metals with complicated shapes can be cleared, the amounts of radioactive waste can be reduced. A clearance verification system is constructed to determine the amount of uranium in decontaminated metals in a drum using the 1.001 MeV gamma rays of 234mPa, produced in the decay of 238U. The experimental study with simulated waste drums demonstrated that the quantification errors of uranium fall within 25% for 0.5 g of uranium.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2018.11.002

Additional details

Identifiers

DOI
10.1016/j.apradiso.2018.11.002;
PII
S0969804318305876;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
145
Journal Page Range
p. 19-23
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.