The influence of gamma radiation on the electro-optical characteristics of CR-39 polymer
Creators
- 1. Department of Physics, Gebze Institute of Technology, PO Box 141, Gebze 41400, Kocaeli (Turkey)
Description
The influence of gamma radiation on the electro-optical properties of CR-39 polymer has been investigated by capacitive and interferometric measurements to see the order and tendency of irradiation effects on polymer CR-39, which is commonly used in track detectors. Seven samples of thickness 760 μm and other dimensions 25 mm x 25 mm have been exposed to gamma radiation in the range of zero to 70 kGy in 10 kGy steps. Experimental results exhibit radiation-dependent degradation even at relatively low doses. Modulation of electronic properties can be exploited as an alternative diagnosis tool. (note)
Availability note (English)
Available online at http://stacks.iop.org/0952-4746/25/93/jrp5_1_007.pdf or at the Web site for the Journal of Radiological Protection (ISSN 1361-6498) http://www.iop.org/Additional details
Identifiers
- URL
- http://stacks.iop.org/0952-4746/25/93/jrp5_1_007.pdf; http://www.iop.org/;
- DOI
- 10.1088/0952-4746/25/1/007;
- PII
- S0952-4746(05)93802-0;
Publishing Information
- Journal Title
- Journal of Radiological Protection
- Journal Volume
- 25
- Journal Issue
- 1
- Journal Page Range
- p. 93-96
- ISSN
- 0952-4746
- CODEN
- JRPREA
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 36029156
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- DIAGNOSIS; GAMMA RADIATION; OPTICAL PROPERTIES; PARTICLE TRACKS; POLYMERS; RADIATION DETECTION; RADIATION DETECTORS; RADIATION DOSES; THICKNESS
- Descriptors DEC
- DETECTION; DIMENSIONS; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; PHYSICAL PROPERTIES; RADIATIONS