High concentration (400 mgI/mL) versus low concentration (320 mgI/mL) iodinated contrast media in multi detector computed tomography of the liver: A randomized, single centre, non-inferiority study
Creators
- 1. Department of Radiological Sciences, Oncology and Pathology, University of Rome "SAPIENZA", Polo Pontino, I.C.O.T., Via Franco Faggiana 34, 04100 Latina (Italy)
- 2. Department of Radiological Sciences, San Giovanni Hospital, Via dell'Amba Aradam 9, 00184 Rome (Italy)
Description
Objectives: To compare vascular and parenchymal contrast enhancement in multidetector computed tomography of the liver using two contrast media with different iodine concentration (Iodixanol 320 mgI/mL and Iomeprol 400 mgI/mL) and similar viscosity, using fixed total iodine volume (40 gI) and iodine delivery rate (1.6 gI/s). Methods: 110 patients were prospectively randomized into two groups. Group A received 125 mL of Iodixanol 320 and group B 100 mL of Iomeprol 400. Attenuation values were measured at the level of the aorta, portal vein and liver parenchyma on unenhanced, arterial, portal and equilibrium phases. A non inferiority test was performed on the differences between the two groups. An independent reader evaluated image quality. Results: The equivalence of the two CM was demonstrated in all measurements. Higher, but not statistically significant, attenuation values were obtained with Iomeprol 400 in the aorta during the arterial phase (305.3 HU versus 288.4 HU; P = 0.32) and with Iodixanol 320 in the liver parenchyma, during both portal (59.8 HU versus 65.5 HU; P = 0.78) and equilibrium (40.4 HU versus 41.8 HU; P = 0.55) phases. Conclusions: Iodixanol 320 and Iomeprol 400 injected at the same iodine delivery rate (1.6 gI/s) and total iodine load (40 gI) did not provide statistically significant differences in liver parenchymal and vascular contrast enhancement.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.05.017Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.05.017;
- PII
- S0720-048X(12)00246-X;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 11
- Journal Page Range
- p. 3096-3101
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45027635
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AORTA; ATTENUATION; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CONCENTRATION RATIO; CONTRAST MEDIA; DELIVERY; DIAGNOSIS; DIGESTIVE SYSTEM DISEASES; IMAGES; IODINE; LIVER; PATIENTS; VASCULAR DISEASES; VEINS; VISCOSITY
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DIMENSIONLESS NUMBERS; DISEASES; ELEMENTS; EVALUATION; GLANDS; HALOGENS; NONMETALS; ORGANS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.