Published June 1987 | Version v1
Journal article

Dosimetry for total body irradiation

Creators

  • 1. Physics Div., Ontario Cancer Inst., Medical Biophysics Dept., Univ. of Toronto (Canada)

Description

Total body irradiation (TBI) is becoming increasingly prominent as a major component of therapy for patients with hematological diseases requiring bone marrow transplantation. This review considers some of the special dosimetric problems associated with TBI. Basic beam dosimetry and factors affecting dose variation within the patient are discussed and compared to conventional radiotherapy. The delivery of an accurate dose to the patient requires phantom measurements to be related to the dose at the prescription point. The use of treatment planning dose calculation procedures, including inhomogeneity corrections, is described specifically for large field treatments. Finally, some questions for future research are considered. (Auth.)

Additional details

Additional titles

Subtitle (English)
Invited paper

Publishing Information

Journal Title
Radiother. Oncol.
Journal Volume
9
Journal Issue
2
Series
Radiother. Oncol.
Journal Page Range
107-118
ISSN
0167-8140
CODEN
RAOND

Conference

Title
Symposium on total body irradiation, 5. ESTRO meeting.
Dates
8-10 Sep 1986.
Place
Baden-Baden (Germany, F.R.).

INIS

Country of Publication
Ireland
Country of Input or Organization
Netherlands
INIS RN
18090346
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DOSIMETRY; HEMIC DISEASES; PHANTOMS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; WHOLE-BODY IRRADIATION
Descriptors DEC
DISEASES; EXTERNAL IRRADIATION; IRRADIATION; MEDICINE; MOCKUP; STRUCTURAL MODELS; THERAPY

Optional Information

Notes
40 refs.; 5 figs.; 1 table.