High temperature reactor module power plant. Plant and safety concept June 1986 - 38.07126.2
Description
The modular HTR power plant is a universally applicable energy source for the co-generation of electricity, process steam or district heating. The modular HTR concept is characterized by the fact that standardized reactor units with power ratings of 200 MJ/s (so-called modules) can be combined to form power plants with a higher power rating. Consequently the special safety features of small high-temperature reactors (HTR) are also available at higher power plant ratings. The safety features, the technical design and the mode of operation are briefly described in the following, taking a power plant with two HTR-Modules for the co-generation of electricity and process steam as an example. Due to its universal applicability and excellent safety features, the modular HTR power plant is suitable for erection on any site, but particularly on sites near other industrial plants or in densely populated areas. The co-generation of electricity and process steam or district heating with a modular HTR power plant as described here is primarily tailored to the requirements of industrial and communal consumers. The site for such a plant is a typical industrial one. The anticipated features of such sites were taken into consideration in the design of the modular HTR power plant
Availability note (English)
Available from INIS in electronic formFiles
37043688.pdf
Files
(1.9 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:d0e53b107037e3622cdef8a3c732bf83
|
1.9 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 40 p.
- Report number
- INIS-XA-N--221
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37043688
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- COGENERATION; DISTRICT HEATING; ELECTRICITY; POWER PLANTS; SAFETY; TEMPERATURE RANGE 0400-1000 K
- Descriptors DEC
- HEATING; POWER GENERATION; STEAM GENERATION; TEMPERATURE RANGE
Optional Information
- Notes
- 10 refs, 14 figs, 2 tabs