SU-D-18C-01: A Novel 4D-MRI Technology Based On K-Space Retrospective Sorting
Creators
- 1. Duke University Medical Center, Durham, NC (United States)
- 2. Medical Physics Program, Durham, NC (United States)
Description
Purpose: Current 4D-MRI techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of an entirely new framework of 4D-MRI based on k-space retrospective sorting. Methods: An important challenge of the proposed technique is to determine the number of repeated scans(NR) required to obtain sufficient k-space data for 4D-MRI. To do that, simulations using 29 cancer patients' respiratory profiles were performed to derive the relationship between data acquisition completeness(Cp) and NR, also relationship between NR(Cp=95%) and the following factors: total slice(NS), respiratory phase bin length(Lb), frame rate(fr), resolution(R) and image acquisition starting-phase(P0). To evaluate our technique, a computer simulation study on a 4D digital human phantom (XCAT) were conducted with regular breathing (fr=0.5Hz; R=256×256). A 2D echo planer imaging(EPI) MRI sequence were assumed to acquire raw k-space data, with respiratory signal and acquisition time for each k-space data line recorded simultaneously. K-space data was re-sorted based on respiratory phases. To evaluate 4D-MRI image quality, tumor trajectories were measured and compared with the input signal. Mean relative amplitude difference(D) and cross-correlation coefficient(CC) are calculated. Finally, phase-sharing sliding window technique was applied to investigate the feasibility of generating ultra-fast 4D-MRI. Result: Cp increased with NR(Cp=100*[1-exp(-0.19*NR)], when NS=30, Lb=100%/6). NR(Cp=95%) was inversely-proportional to Lb (r=0.97), but independent of other factors. 4D-MRI on XCAT demonstrated highly accurate motion information (D=0.67%, CC=0.996) with much less artifacts than those on image-based sorting 4D-MRI. Ultra-fast 4D-MRI with an apparent temporal resolution of 10 frames/second was reconstructed using the phase-sharing sliding window technique. Conclusions: A novel 4D-MRI technology based on k-space sorting has been successfully developed and evaluated on the digital phantom. Framework established can be applied to a variety of MR sequences, showing great promises to develop the optimal 4D-MRI technique for many radiation therapy applications. NIH (1R21CA165384-01A1)
Additional details
Identifiers
- DOI
- 10.1118/1.4887909;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 41
- Journal Issue
- 6
- Journal Page Range
- p. 120
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46040288
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- CARBON 18; COMPUTERIZED SIMULATION; DATA ACQUISITION; IMAGES; NEOPLASMS; NMR IMAGING; PATIENTS; PHANTOMS; RADIOTHERAPY; RESPIRATION; SPATIAL RESOLUTION
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CARBON ISOTOPES; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DISEASES; EVEN-EVEN NUCLEI; ISOTOPES; LIGHT NUCLEI; MEDICINE; MILLISECONDS LIVING RADIOISOTOPES; MOCKUP; NUCLEAR MEDICINE; NUCLEI; PROCESSING; RADIOISOTOPES; RADIOLOGY; RESOLUTION; SIMULATION; STRUCTURAL MODELS; THERAPY
Optional Information
- Notes
- (c) 2014 American Association of Physicists in Medicine