RTNS-II targets: cooling channel collapse under simulated bonding conditions

Description

We experimentally determined the pressure limits that can be used to autoclave-bond RTNS-II targets without crushing the internal cooling channels. The maximum pressures are 40 to 55 MPa (6 to 8 ksi) in the 300-to-4500C temperature regime