Implementation of a QA programme at the diagnostic radiology calibration laboratory of IPEN
- 1. Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)
Description
The Calibration Laboratory of the Instituto de Pesquisas Energeticas e Nucleares (LCI) has, for over 25 years, has been calibrating instruments used in radiation protection, therapy and diagnostic radiology measurements belonging to hospitals, industries, clinics and other users. The number of annually tested instruments, about 2000, needs development and implementation of a quality assurance system to facilitate the management of the routine procedures and their improvement. The LCI has already established a quality assurance programme in order to achieve accreditation of the calibration activities following the requirements of the ABNT ISO/IEC 17025. The quality manual and all procedures, including the uncertainty analysis, are ready. The Calibration Laboratory has undertaken three internal audits and an external audit performed by the Evaluation Committee of the Calibration Laboratories linked to the National Institute of Metrology, Normalization and Industry Quality (INMETRO), Brazil. The quality assurance system of the LCI follows also the requirements of the Integrated Management Quality System of IPEN, and it can be described by its main characteristics: Organization. The Calibration Laboratory of IPEN is part of the Radiation Metrology Center (CMR). LCI quality mission. Calibration of radiation detectors in order to guarantee more accuracy in the measurements and in the radiation use . Documentation system. It follows the hierarchy shown. Technical requirements. (a) Staff: The technical manager of LCI authorizes and keeps the registers of all authorizations, professional and educational qualifications, training, abilities and experience of the staff. (b) Main reference dosimetric systems: PTW spherical ionization chamber, 1000 cm3, model LS01, traceable to LNMRI, Brazil (radiation protection level); NE cylindrical ionization chamber, 0.6 cm3, model 2505/3, traceable to LNMRI, Brazil (radiation therapy level); PTW parallel plate ionization chamber, 1 cm3, model 77334, traceable to PTB, Germany (diagnostic radiology level, conventional qualities), Radcal parallel plate ionization chamber, 6 cm3, model 20x5-6M, traceable to FDA, USA (diagnostic radiology level, mammography qualities). (c) Traceability: The LCI calibration programme of all instruments is traceable to the International Systems of Units (SI); therefore, all reference systems are periodically calibrated or intercompared to the standards of the Ionizing Radiation Metrology National Laboratory (LNMRI). If these procedures are not possible, the instrument has to be sent to an international secondary or primary laboratory. (d) Calibration procedures and best measurement capacity: The LCI uses adequate methods and procedures for all kinds of calibration services offered, including handling, transport and storage space; preparation of the items to be calibrated; and the determination of the measurement uncertainties. For the calibration of diagnostic radiology instruments, the radiation qualities recommended by the IEC 61267 standard were established. The best capacity of measurement for the calibrations applied to diagnostic radiology instruments is shown. A calibration report is issued for each calibration service realized by the LCI, which includes all the necessary information for the interpretation of the results, including the measurements traceability
Additional details
Publishing Information
- Imprint Title
- International conference on quality assurance and new techniques in radiation medicine. Book of extended synopses
- Imprint Pagination
- 584 p.
- Journal Page Range
- p. 306-307
- Report number
- IAEA-CN--146
Conference
- Title
- International conference on quality assurance and new techniques in radiation medicine
- Dates
- 13-15 Nov 2006
- Place
- Vienna (Austria)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38002667
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; BIOMEDICAL RADIOGRAPHY; BRAZIL; CALIBRATION; CALIBRATION STANDARDS; HOSPITALS; IONIZATION CHAMBERS; IONIZING RADIATIONS; MAMMARY GLANDS; QUALITY ASSURANCE; RADIATION PROTECTION; RADIATION QUALITY; RADIOTHERAPY; TRAINING
- Descriptors DEC
- BODY; BUILDINGS; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; EDUCATION; GLANDS; LATIN AMERICA; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATION DETECTORS; RADIATIONS; RADIOLOGY; SOUTH AMERICA; STANDARDS; THERAPY
Optional Information
- Notes
- 2 refs, 2 tabs
- Secondary number(s)
- IAEA-CN--146/195P