Improve mechanical strength of KCT-300 TL pellet
Description
P-compound of 10mol%(about 7.8wt%) embedded CaSO4:Dy TL pellet(KCT-300) was developed by KAERI. KCT-300 has high sensitivity and good dosimetric characteristics than Teflon embedded CaSO4:Dy TL pellet. But, mechanical strength of KCT-300 is not good. Essentially the mechanical strength is improved with increased the P-compounds concentration, but TL sensitivity is decreased relatively. In the case of high P-compounds concentration, surface of KCT-300 is rugged after sintering. So, it is too difficult that improve the mechanical strength of KCT-300 as raise P-compounds concentrate. This paper presented the method for raise mechanical strength of KCT-300. In this research, high temperature treatment process after P-compounds embedded CaSO4:Dy TL phosphor added to fabrication process of KCT-300
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- [CD-ROM]
- Journal Page Range
- [5 p.]
Conference
- Title
- 2003 Spring meeting of the KNS
- Dates
- 29-30 May 2003
- Place
- Gyeongju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 35064116
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CALCIUM SULFATES; DOSIMETRY; FABRICATION; FUEL PELLETS; PHOSPHORS; SENSITIVITY; SINTERING; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- ALKALINE EARTH METAL COMPOUNDS; CALCIUM COMPOUNDS; DOSEMETERS; FABRICATION; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; OXYGEN COMPOUNDS; PELLETS; SULFATES; SULFUR COMPOUNDS
Optional Information
- Notes