Published 2023 | Version v1
Miscellaneous Open

Examination of parameters influencing the image quality and patients' doses during computer tomography imaging method and determination of diagnostic reference levels

  • 1. Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, 'Ss. Cyril and Methodius University', Skopje (North Macedonia, Republic of)
  • 2. Institute of Physics, Faculty of Natural Sciences and Mathematics, 'Ss. Cyril and Methodius University', Skopje (North Macedonia, Republic of)

Description

The Diagnostic Reference Level (DRL), is an important tool for dose monitoring and optimizing diagnostic imaging modalities, such as Computed Tomography (CT). Image quality gained by CT scan correlates with the patient's effective dose. The purpose of this study was: to determine DRLs; research the potential of optimization in the acquisition protocols and diagnostic quality of images. This research is conducted in three hospitals across North Macedonia in period 2016-2021, all using GE Bright Speed CT scanner with AEC system. Clinical protocols for abdominal regions and head were considered. A total of 287 CT scans were analyzed. Results have shown that: there are differences in the number of series and acquisition parameters, particularly in the abdominal studies. Variations in the average CTDIvol values were noticed in similar patients (by size). In addition, no correlation between scan range and patient height compromised the assessment of the DLP value per type of examination. A difference in DLP greater than 25% was evident for similar patients in height, especially among the contrast phases. Finally, the same image quality was provided in examinations differing by even double value in the CTDIvol. Therefore, the clinical protocol for abdominal scans needs to be standardized and optimized according to the clinical indication. (author)

Files

54067093.pdf

Files (3.1 MB)

Name Size Download all
md5:582253c28bbbdba9c439f0ecd9bb4d57
3.1 MB Preview Download
Part of:
Conference Proceedings of the 14th Conference of the Society of Physicists of Macedonia CSPM2022

Additional details

Publishing Information

Publisher
Society of Physicists of Macedonia - DFRM, Skopje
Imprint Place
Skopje (North Macedonia, Republic of)
ISBN
978-608-4711-15-5
Imprint Title
Conference Proceedings of the 14th Conference of the Society of Physicists of Macedonia CSPM2022
Imprint Pagination
128 p.
Journal Page Range
p. 71-74
Report number
INIS-MK--2300008

Conference

Title
14. Conference of the Society of Physicists of Macedonia
Acronym
CSPM 2022
Dates
15-18 Sep 2022
Place
Ohrid (North Macedonia, Republic of)

INIS

Country of Publication
North Macedonia, Republic of
Country of Input or Organization
North Macedonia, Republic of
INIS RN
54067093
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; DOSES; HOSPITALS; IMAGE PROCESSING; LEVELS; MULTI-PARAMETER ANALYSIS; NORTH MACEDONIA; PATIENTS; QUALITY CONTROL
Descriptors DEC
BUILDINGS; CONTROL; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; EASTERN EUROPE; EUROPE; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; TOMOGRAPHY

Optional Information

Notes
13 refs., 2 figs., 2 tabs.; UDC: 616-073.756.8:004]:539.166.089.6