Published April 1980 | Version v1
Journal article

An improved system for fast, continuous chemical separations ('SISAK 2') in nuclear spectroscopic studies

  • 1. Chalmers Tekniska Hoegskola, Goeteborg (Sweden). Dept. of Nuclear Chemistry
  • 2. Oslo Univ. (Norway). Dept. of Nuclear Chemistry
  • 3. Mainz Univ. (Germany, F.R.). Inst. fuer Kernchemie

Description

An improved rapid, continuous solvent extraction system is described. The system is connected to a gas-jet installed at the Mainz reactor. It allows single or multistage chemical separations of liquid phases by means of specially designed centrifuges within approx. 1 s per stage. The application of this system to study short-lived nuclides is exemplified for neutron-rich lanthanum and cerium isotopes produced by fission. (orig./HP)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
171
Journal Issue
2
Series
Nucl. Instrum. Methods.
Journal Page Range
323-328
ISSN
0029-554X