Published 2005 | Version v1
Journal article

Characterisation of a neutron beam available at the RPI using a set of Bonner spheres

  • 1. I.T.N., Estrada Nacional 10, P-2686-953 Sacavem (Portugal)

Description

The use of Bonner spheres to characterise radiation fields is abundantly documented in the literature. This study, carried out using the state-of-the-art Monte Carlo code MCNPX and the deconvolution program MAXED, aims to characterise the RPI epithermal neutron beam using of a set of Bonner spheres of different radii surrounding a 3He detector. The energy range of interest in this study covers from thermal to 10 MeV. This purely computational study aims to assess the feasibility of using the method previously mentioned to improve the knowledge of the energy and intensity characteristics of the epithermal beam. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nci017

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
116
Journal Issue
1-4
Journal Page Range
p. 77-80
ISSN
0144-8420

Conference

Title
10. International Conference on Radiation Shielding, and 13. ANS Topical Meeting on Radiation Protection and Shielding - ICRS-10/RPS 2004
Dates
9-14 May 2004
Place
Funchal, Madeira Island (Portugal)

Optional Information

Notes
6 refs