Design of tritium handling system(II): Injection system, regeneration system
- 1. KEPRI, Taejon (Korea, Republic of)
Description
In succession to the previous paper, the tritium injection system and the regeneration system of the tritium handling system are presented. Both systems should be placed inside glove boxes since there can be potential leakage of tritium from these systems. The tritium injection system should be capable of measuring the exact amount of the injected tritium to keep track of the tritium inventory. The tritium injection system is designed to recover the remaining tritium from the system after injection for the minimization of tritium release to the environment as well as for the recovery of precious resource. TRS equipment such as MS, Ni catalyst bed, and metal getter are regenerated with a standalone regeneration system. Unlike other equipments which can be regenerated by heating and purging with appropriate gas, regeneration of the metal getter used to recover tritium is somewhat complicated
Additional details
Publishing Information
- Publisher
- KRWS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the Korean Radioactive Waste Society Fall, 2003
- Imprint Pagination
- 724 p.
- Journal Page Range
- p. 117-123
Conference
- Title
- 2003 Fall Meeting of the Korean Radioactive Waste Society
- Dates
- 27-29 Nov 2003
- Place
- Cheju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36017061
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DESIGN; GLOVEBOXES; INJECTION; LEAKS; TRITIUM
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; EQUIPMENT; HYDROGEN ISOTOPES; INTAKE; ISOTOPES; LABORATORY EQUIPMENT; LIGHT NUCLEI; NUCLEI; ODD-EVEN NUCLEI; RADIOISOTOPES; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 19 refs, 2 figs