Published 1999 | Version v1
Computer medium

Study on in-service visual inspection using TV camera for core support graphite components in the HTTR

  • 1. Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

Description

To maintain the structural integrity of graphite components during plant operation a visual inspection using a TV camera as an in-service inspection is planned in the High Temperature Engineering Test Reactor. In order to verify the in-service inspection method a preliminary analytical and experimental studies were performed. In the analytical study the harmful flaw size was determined from a viewpoint of structural integrity based on the fracture mechanics approach. Furthermore, the visible flaw size was determined by the TV camera performance test with graphite test specimens having several kinds of artificial flaws. This paper presents the analytical result on the harmful flaw size and the experimental result on the visible flaw size. From both results the applicability on the visual inspection by the TV camera as the in-service inspection is discussed in this paper. (author)

Part of:
ICONE-7: Proceedings of the 7th international conference on nuclear engineering

Additional details

Publishing Information

Publisher
Japan Society of Mechanical Engineers
Imprint Place
Tokyo (Japan)
Imprint Title
ICONE-7: Proceedings of the 7th international conference on nuclear engineering
Imprint Pagination
4252 p.
Journal Page Range
[10 p.]

Conference

Title
7. international conference on nuclear engineering
Acronym
ICONE-7
Dates
19-23 Apr 1999
Place
Tokyo (Japan)

Optional Information

Notes
This CD-ROM can be used for WINDOWS 95/98/NT, MACINTOSH and UNIX; Acrobat Reader 3.0.1 is included; Data in PDF format, Track No. 02, ICONE-7039