Published 1976
| Version v1
Miscellaneous
Routine testing of radioactive aerosol filters
Creators
Description
A method is described for state routine testing of radioactive aerosol filters used in nuclear engineering in DDR. Standard polydispersed aerosola with the particle size less than 1 μ are used. The dispersion of aerosols is measured before and behind the filter to determine the filtration factor as a function of the particle size. As an example a fiber glass filter and NaCl aerosola are considered. The performance testing is conducted at the filter productivity of 650 m3/hr. The maximum filtration factor has been found to correspond to the approximate particle size of 0.15 μ. The filtration factor depends strongly on the particle size
Additional details
Additional titles
- Original title (Russian)
- Типовое испытание фильтров для улавливания радиоактивных аэрозолей
Publishing Information
- Publisher
- Czechoslovakian Atomic Energy Commission.
- Imprint Place
- Prague
- Imprint Title
- Problems of radiation safety provisions at nuclear power plants operation. Vol. 2
- Journal Page Range
- p. 35-37.
- Report number
- INIS-mf--6307
Conference
- Title
- Scientific and technical conference of CMEA.
- Dates
- 8 - 12 Sep 1975.
- Place
- Usti nad Labem, Czechoslovakia.
INIS
- Country of Publication
- International Centre for Scientific and Technical Information (ICSTI)
- Country of Input or Organization
- International Centre for Scientific and Technical Information (ICSTI)
- INIS RN
- 12627577
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EFFICIENCY; FILTERS; FILTRATION; PARTICLE SIZE; PERFORMANCE TESTING; RADIOACTIVE AEROSOLS
- Descriptors DEC
- AEROSOLS; COLLOIDS; DISPERSIONS; SEPARATION PROCESSES; SIZE; SOLS; TESTING
Optional Information
- Notes
- 3 figs. Imprint:Problemy obespecheniya radiatsionnoj bezopasnosti pri ehkspluatatsii atomnykh ehlektrostantsij. Tom 2.;Sbornik dokladov.