Published 1976 | Version v1
Miscellaneous

Routine testing of radioactive aerosol filters

Description

A method is described for state routine testing of radioactive aerosol filters used in nuclear engineering in DDR. Standard polydispersed aerosola with the particle size less than 1 μ are used. The dispersion of aerosols is measured before and behind the filter to determine the filtration factor as a function of the particle size. As an example a fiber glass filter and NaCl aerosola are considered. The performance testing is conducted at the filter productivity of 650 m3/hr. The maximum filtration factor has been found to correspond to the approximate particle size of 0.15 μ. The filtration factor depends strongly on the particle size

Additional details

Additional titles

Original title (Russian)
Типовое испытание фильтров для улавливания радиоактивных аэрозолей

Publishing Information

Publisher
Czechoslovakian Atomic Energy Commission.
Imprint Place
Prague
Imprint Title
Problems of radiation safety provisions at nuclear power plants operation. Vol. 2
Journal Page Range
p. 35-37.
Report number
INIS-mf--6307

Conference

Title
Scientific and technical conference of CMEA.
Dates
8 - 12 Sep 1975.
Place
Usti nad Labem, Czechoslovakia.

INIS

Country of Publication
International Centre for Scientific and Technical Information (ICSTI)
Country of Input or Organization
International Centre for Scientific and Technical Information (ICSTI)
INIS RN
12627577
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
EFFICIENCY; FILTERS; FILTRATION; PARTICLE SIZE; PERFORMANCE TESTING; RADIOACTIVE AEROSOLS
Descriptors DEC
AEROSOLS; COLLOIDS; DISPERSIONS; SEPARATION PROCESSES; SIZE; SOLS; TESTING

Optional Information

Notes
3 figs. Imprint:Problemy obespecheniya radiatsionnoj bezopasnosti pri ehkspluatatsii atomnykh ehlektrostantsij. Tom 2.;Sbornik dokladov.