Intensity of steam condensation in a subcooled water

Description

Simplified technique for calculating steam condensation intensity in a turbulent flow of subcooled water is described. The technique is based on the model of heat and mass transfer between a steam bubble and surrounding water. The technique was tested when processing results of experiments on steam condensation with mixing of two-phase flow and subcooled water in a tube 145 mm in diameter. The obtained data have supported the technique applicability in the following range of operating parameters: pressure p=2-4 MPa, the rate of steam bubble movement W=0.45-1.78 m/s, water subcooling Δt=0.1-2.0 K

Additional details

Additional titles

Original title (Russian)
Интенсивность конденсации пара в недогретой воде

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
64
Journal Issue
1
Series
At. Ehnerg.
Journal Page Range
62-65
ISSN
0004-7163
CODEN
AENGA

INIS

Country of Publication
Russian Federation
Country of Input or Organization
USSR
INIS RN
20006170
Subject category
S42: ENGINEERING;
Descriptors DEI
BUBBLES; HEAT TRANSFER; MASS TRANSFER; MATHEMATICAL MODELS; MEDIUM PRESSURE; SUBCOOLING; TURBULENT FLOW; TWO-PHASE FLOW; VAPOR CONDENSATION; WATER; WATER VAPOR
Descriptors DEC
COOLING; ENERGY TRANSFER; FLUID FLOW; FLUIDS; GASES; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; POLAR SOLVENTS; SOLVENTS; VAPORS