Published May 2008 | Version v1
Journal article

Effects of tube inclination on saturated nucleate pool boiling heat transfer

  • 1. Andong National Univ., Andong (Korea, Republic of)

Description

Effects of tube inclination on pool boiling heat transfer have been studied for the saturated water at atmospheric pressure. For the analysis, seven inclination angles varying from the horizontal to the vertical and two tube diameters(25.4 and 30.0 mm) are tested. According to the results, inclination angles result in much change on heat transfer. For the same wall superheat (about 5.3 .deg. C) the ratio between two heat fluxes for the 45 .deg. inclined and the vertical has the value of more than five when the tube diameter is 25.4mm. As the inclination angle is increasing from the horizontal to the vertical direction heat transfer is gradually increasing because of the increase in liquid agitation. However the detailed tendency depends on the ratio between the tube length and the diameter

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
32
Journal Issue
5
Series
15 refs, 7 figs, 1 tab
Journal Page Range
p. 327-334
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
40071976
Subject category
S42: ENGINEERING;
Descriptors DEI
CRITICAL HEAT FLUX; HEAT TRANSFER; INCLINATION; POOL BOILING; ROUGHNESS; SURFACES; TUBES
Descriptors DEC
BOILING; ENERGY TRANSFER; HEAT FLUX; PHASE TRANSFORMATIONS; SURFACE PROPERTIES