Published March 1995 | Version v1
Journal article

A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

In this paper the method to evaluate shielding deficiency by gamma scanning test was presented and verified theoretically by Monte Carlo code which is one of the best effective method for radiation shielding calculation. The cylindrical shielding model was selected to evaluate shielding deficiency by gamma scanning test. First, the reference shielding according to the design requirement of cask was fabricated specially and reference values were measured with Co-60 source and scintillation detector. As a result with which calculated the reference values, it is shown that maximum deficiency thickness for lead of true cylindrical shielding model was 12mm. To verify this, thickness of lead was calculated by MCNP code and maximum deficiency thickness was 11.6mm. The experimental result obtained by the use of reference shielding was in good agreement with the theoretical result within 4.1%. So, this method can be applied to inspect the shielding ability for great shielding or cask which the radioactive material is used. To perform measurement more exactly, the further work on the development of measuring equipment to display the results on the screen will be required

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Nondestructive Testing
Journal Volume
14
Journal Issue
4
Series
13 refs, 6 figs, 4 tabs
Journal Page Range
p. 228-236
ISSN
1225-7842

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
42102690
Subject category
S42: ENGINEERING;
Descriptors DEI
COMPUTER CALCULATIONS; DESIGN; M CODES; MONTE CARLO METHOD; RADIATIONS; RADIOACTIVE MATERIALS; SHIELDING
Descriptors DEC
CALCULATION METHODS; COMPUTER CODES; MATERIALS