Published June 28, 2000 | Version v1
Miscellaneous Open

Evaluation Of Reactor Coolant System Of Design Of Bandung TRIGA Mark II 2 MW Reactor

  • 1. Center for Development Nuclear Safety Technology, National Nuclear Energy Agency, Serpong (Indonesia)

Description

An evaluation of reactor coolant system of Bandung TRIGA Mark II has been carried out. The evaluation is conducted for primary and secondary system, both for steady state and transient conditions. The evaluation is based on the analysis results done by the operator. In the steady state (i.e. normal operation), the maximum temperature of fuel element is 569.7C. A series of analysis covering various accident scenarios of LOPA and LOCA shows that the coolant system and ECCS able to maintain the fuel temperature less then 970C, then the fuel integrity is kept safe. However, the detail analysis using validated codes is still needed to support the actual safety analysis

Files

34007387.pdf

Files (191.7 kB)

Name Size Download all
md5:5c278c156395d524971784e53d162a5e
191.7 kB Preview Download
Part of:
Proceeding of the Fifth Scientific Presentation on Nuclear Safety Technology

Additional details

Additional titles

Original title (Indonesian)
Evaluasi Disain Sistem Pendingin Reaktor TRIGA MARK II Bandung Daya 2 MW

Publishing Information

Publisher
Center for Development Nuclear Safety Technology, National Nuclear Energy Agency
Imprint Place
Serpong (Indonesia)
Imprint Title
Proceeding of the Fifth Scientific Presentation on Nuclear Safety Technology
Imprint Pagination
314 p.
Journal Page Range
p. 237-246
ISSN
1410-0533
Report number
INIS-ID--019

Conference

Title
5. Scientific Presentation on Nuclear Safety Technology
Original Conference Title
Presentasi Ilmiah Teknologi Keselamatan Nuklir V
Dates
28 Jun 2000
Place
Serpong (Indonesia)

Optional Information

Notes
4 figs; 6 refs; 1 tabs