Description

It is a well-known fact that the breakdown voltage of dielectrics in a divergent field may be increased by using an additional insulating layer (a barrier) placed at the optimal position between the electrodes. This paper is devoted to the investigation of the barrier effect in solid dielectrics in a quasi-uniform electric field, i.e. the study of the relationship between partial discharge (PD) activity and the barrier position in the insulating gap. It is established that the PD parameters depend on the barrier position in the gap. In particular, the ignition voltage of critical PDs is increased by more than 50% at the optimal barrier position compared to that for other barrier positions

Availability note (English)

Available online at http://stacks.iop.org/0022-3727/37/3155/d4_22_016.pdf or at the Web site for the Journal of Physics. D, Applied Physics (ISSN 1361-6463) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Journal of Physics. D, Applied Physics
Journal Volume
37
Journal Issue
22
Journal Page Range
p. 3155-3159
ISSN
0022-3727
CODEN
JPAPBE

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
36037195
Subject category
S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Descriptors DEI
BREAKDOWN; DIELECTRIC MATERIALS; ELECTRIC DISCHARGES; ELECTRIC FIELDS; ELECTRODES; LAYERS; PERMITTIVITY; SOLIDS
Descriptors DEC
DIELECTRIC PROPERTIES; ELECTRICAL PROPERTIES; MATERIALS; PHYSICAL PROPERTIES