Published 1996 | Version v1
Book

Radon concentrations in Taipei metropolitan railway station

  • 1. Qinghua Univ., Beijing, BJ (China)

Description

For routine airborne radon monitoring, including use in field conditions, the technique based on electret ion chamber technology seems to be the most suitable choice in many applications. However, this simple and relatively inexpensive method has some specific drawbacks: poorer reproducibility at lower radon concentrations, some uncertainty in the use of manufacturer suggested gamma correction factors, and limited reusability. A modified electret ion chamber method has been proposed, but it is mainly for water borne radon measurement. Therefore, we still applied the simple method recommended by the manufacturer to survey radon concentrations in Taipei Railway Station. (author)

Part of:
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 2

Additional details

Publishing Information

Publisher
Berger.
Imprint Place
Horn (Austria)
ISBN
3-9500255-4-5
Imprint Title
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 2
Imprint Pagination
817 p.
Journal Page Range
p. 89-91.