Published 1985 | Version v1
Miscellaneous Open

Calculating of radiation doses in rutinary unloads of liquid wastes from Laguna Verde nuclear power plant

Description

Utilization of nuclear energy to produce or generate electricity is a growing practice in the world, since it represent an economic and safe option to replace fossil fuels. During operation of nuclear power plants, radioactive materials are produced. A small fraction of these material are released to environment in the form of liquid or gaseous effluents. Estimation of radiation doses causing by effluents release has three purposes. During design phase of a nuclear station it is useful to adapt the wastes treatment systems to acceptable limits. During licensing phase, the regulator organism verifies the design of nuclear station effectuating estimation of doses. Finally, during operation of a nuclear station, before every unload of radioactive effluents, radiation doses should be evaluate in order to fulfill technical specifications, which limit the release of radioactive materials to environment. 1. To perform calculations of individual doses due to liquid radioactive effluents unload in units 1 and 2 of Laguna Verde nuclear power plant (In licensing phase). 2. To perform a parametric study of the effect of unload recirculation over individual dose, since recirculation has two principal effects: thermodynamical effects in nuclear station and radioactivity concentration, the last can affect the fullfilment of dose limits. 3. To perform the calculation of collective doses causes by unloads of liquid effluents within a radius of 80 Kms. of nuclear station caused by unload of liquid radioactive effluents during normal operation of nuclear power plant and does not include doses caused during accident conditions. In Mexico the organism in charge of regulation of peaceful uses of nuclear energy is Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) and for Laguna Verde licensing, the regulations of country who manufactured the reactor was adopted, it is to say United States of America. In Appendix 'C' units used along this work are explained. Unless another thing is specified the term 'doses' will be used instead of 'engaged equivalent of doses'. Calculating models used to compute doses, were developed in USA Nuclear Regulatory Commission (NRC), based upon models of publication number 2 of International Commission of Radiological Protection. Based on this models, NRC worked out a computer code named LADTAP, which was used to perform calculations of the thesis. Computer code LADTAP was adopted and used in a CDC-660 computer (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

24001003.pdf

Files (2.3 MB)

Name Size Download all
md5:c14d550720dbdb25f9d4bffe9c6d68e1
2.3 MB Preview Download

Additional details

Additional titles

Original title (Spanish)
Calculo de las dosis de radiacion debidas a las descargas rutinarias de desechos liquidos de la central nucleoelectrica de Laguna Verde

Publishing Information

Imprint Pagination
138 p.
Report number
INIS-mf--13396