Water vapor injections in HFR-K 6. Experimental design
Description
Automatic translation: There is still no verified model to describe the Humidity influence on the inert gas and iodine release from defective TRISO particles with UO2 cores, although this effect in the flooding accident of the HTR module dominant for the radiological rating could be. The original proposal based on this the humidity-related Xe-133 release of 2 HFR-K6 test elements after irradiation as quickly as possible in the KORA apparatus measuring the KFA cannot be realized. Therefore, in ongoing HFR-K6 irradiation test several water vapor injections be carried out in which 9 noble gas nuclides directly during of the injections and 2 iodine nuclides indirectly after the last injection be measured. The fuel assemblies of capsules A and C are selected as test specimens. There are no defect particles in capsule A, so here the humidity effect on the release of fission products Matrix contamination is measured. With capsule C, its test element 2 contains defect particles, the influence of moisture on exposed UO2 cores examined.
Abstract (German)
Es gibt noch kein verifiziertes Modell zur Beschreibung des Feuchteeinflusses auf die Edelgas- und Jodfreisetzung aus defekten TRISO-Partikeln mit UO2-Kernen, obwohl dieser Effekt beim Wassereinbruchsstörfall des HTR-Modul dominierend für die radiologische Bewertung sein könnte. Der damit begründete ursprüngliche Vorschlag, die feuchtebedingte Xe-133 Freisetzung von 2 HFR-K6-Testelementen nach Bestrahlung möglichst schnell in der KORA-Apparatur der KFA zu messen, kann nicht realisiert werden. Deshalb sollen im laufenden Bestrahlungsversuch HFR-K6 mehrere Wasserdampfinjektionen durchgeführt werden, bei denen 9 Edelgasnuklide direkt während der Injektionen und 2 Jodnuklide indirekt nach der letzten Injektion gemessen werden. Als Testproben werden die Brennelemente von Kapsel A und C gewählt. In Kapsel A befinden sich keine Defektpartikel, so daß hier der Feuchteeffekt auf die Freisetzung von Spaltprodukten der Matrixkontamination gemessen wird. Mit Kapsel C, deren Testelement 2 Defektpartikel enthält, wird der Feuchteeinfluß auf exponierte UO2-Kerne untersucht.
Files
Additional details
Additional titles
- Original title (German)
- Wasserdampfinjektionen in HFR-K 6. Versuchsauslegung
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- INIS-DE--22M0226
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 53047002
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S36: MATERIALS SCIENCE;
- Descriptors DEI
- DEFECTS; DESIGN; FEDERAL REPUBLIC OF GERMANY; FISSION PRODUCT RELEASE; FORSCHUNGSZENTRUM JUELICH; FUEL ASSEMBLIES; HTGR TYPE REACTORS; IODINE; IRRADIATION; RARE GASES; URANIUM DIOXIDE; WATER VAPOR; XENON 133
- Descriptors DEC
- ACTINIDE COMPOUNDS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CHALCOGENIDES; DAYS LIVING RADIOISOTOPES; DEVELOPED COUNTRIES; ELEMENTS; EUROPE; EVEN-ODD NUCLEI; FLUIDS; GAS COOLED REACTORS; GASES; GERMAN FR ORGANIZATIONS; GRAPHITE MODERATED REACTORS; HALOGENS; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; NATIONAL ORGANIZATIONS; NONMETALS; NUCLEI; OXIDES; OXYGEN COMPOUNDS; RADIOISOTOPES; REACTORS; URANIUM COMPOUNDS; URANIUM OXIDES; VAPORS; WESTERN EUROPE; XENON ISOTOPES
Optional Information
- Notes
- Document from Juelich Preservation Project; 1 fig.