Published January 1, 2002
| Version v1
Report
SNS LINAC Wire Scanner System: Signal Levels and Accuracy
Description
The linac wire scanner system for the Spallation Neutron Source (SNS) at Oak Ridge, TN, USA, calls for 5 units in the medium energy beam transport (MEBT), 5 in the drift tube linac (DTL), and 10 in the coupled cavity linac (CCL). In this paper we present expected signal levels and an analysis of the error in the beam size measurement as functions of wire position and electrical signal errors.
Availability note (English)
Available from http://lib-www.lanl.gov/cgi-bin/getfile?01045090.pdf; PURL: https://www.osti.gov/servlets/purl/976254-mwbSsK/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- LA-UR--02-4934
Conference
- Title
- 21. International Linac Conference
- Acronym
- LINAC 2002
- Dates
- 19-23 Aug 2002
- Place
- Gyeongju (Korea, Republic of)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 41073054
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ACCURACY; BEAM TRANSPORT; DRIFT TUBES; LINEAR ACCELERATORS; NEUTRON SOURCES; SPALLATION
- Descriptors DEC
- ACCELERATORS; NUCLEAR REACTIONS; PARTICLE SOURCES; RADIATION SOURCES
Optional Information
- Funding organization
- US Department of Energy (United States)