Published December 1, 2006
| Version v1
Journal article
Electronically swept millimeter-wave interferometer for spatially resolved measurement of plasma electron density
Creators
Description
We report the development and initial implementation of what we believe to be a new rapid-spatial-scan millimeter-wave interferometer for plasma density measurements.The fast scan is effected by electronic frequency sweeping of a wideband(180-280 GHz) backward-wave oscillator whose output is focused onto a fixed blazed diffraction grating. The system, which augments the rotating-grating scanned multiview H-1 heliac interferometer, can sweep the plasma cross section in a period of less than 1 ms with a beam diameter in the plasma of 20 mm and phase noise of the order of 0.01 rad
Additional details
Identifiers
- DOI
- 10.1364/AO.45.008613;
Publishing Information
- Journal Title
- Applied Optics
- Journal Volume
- 45
- Journal Issue
- 34
- Journal Page Range
- p. 8613-8620
- ISSN
- 0003-6935
- CODEN
- APOPAI
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38026978
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CROSS SECTIONS; DIFFRACTION GRATINGS; ELECTRON DENSITY; GHZ RANGE 100-1000; H-1 HELIAC; INTERFEROMETERS; INTERFEROMETRY; OSCILLATORS; PLASMA; PLASMA DENSITY; VISIBLE RADIATION
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; EQUIPMENT; FREQUENCY RANGE; GHZ RANGE; HELIAC STELLARATORS; MEASURING INSTRUMENTS; RADIATIONS; STELLARATORS; THERMONUCLEAR DEVICES