Electronically swept millimeter-wave interferometer for spatially resolved measurement of plasma electron density

Description

We report the development and initial implementation of what we believe to be a new rapid-spatial-scan millimeter-wave interferometer for plasma density measurements.The fast scan is effected by electronic frequency sweeping of a wideband(180-280 GHz) backward-wave oscillator whose output is focused onto a fixed blazed diffraction grating. The system, which augments the rotating-grating scanned multiview H-1 heliac interferometer, can sweep the plasma cross section in a period of less than 1 ms with a beam diameter in the plasma of 20 mm and phase noise of the order of 0.01 rad