Published December 1999 | Version v1
Journal article

Flaw Depth Evaluation of Primary Water Stress Corrosion Cracking in Steam Generator Tubings

Creators

  • 1. Sun-Moon University, Asan (Korea, Republic of)

Description

Flaw depth evaluation was performed on the primary water stress corrosion cracking in steam generator tubing, with the eddy current test results such as signal amplitude and phase angle. The relationship between crack length and crack depth was also investigated, based on the metallographic results of pulled-out tubings. This study yields the following results and conclusions: (1) there is no direct correlation between crack length and crack depth. (2) it is not easy to correlate the crack depth with phase angle, (3) although signal amplitude appears to be related with crack length, the latter cannot exactly be obtained from the former value, (4) it would be helpful to sleeve or plug those tubings with crack lengths greater than 5mm, taking into account the present ECT measurement error of 1.5mm, and the fact that most cracks with the length above 7mm could be a through-crack

Additional details

Publishing Information

Journal Title
Journal of the Corrosion Science Society of Korea
Journal Volume
28
Journal Issue
6
Series
6 refs, 6 figs, 3 tabs
Journal Page Range
p. 449-453
ISSN
0253-312X

INIS