A pressure drop study for packed bed adsorption thermal energy storage

  • 1. Laboratory for Alternative Energy Conversion (LAEC), School of Mechatronic Systems Engineering, Simon Fraser University, BC, V3T 0A3 (Canada)

Description

Highlights: • Experimental and modeling study is performed on pressure drop inside adsorber beds. • The model covers a wide range of porosity, from low to high permeability medium. • A modified permeability is defined to consider inertial effects. • The experiment reveals negligible effect of water uptake on pressure drop. • The model shows slight change in pressure drop due to heat of adsorption. Adsorption thermal energy storage has received considerable attention as it can overcome the mismatch between supply and demand of renewables, providing high energy storage per volume. In the packed bed adsorption thermal energy storage, pressure drop is of key concern since higher pressure drop leads into lower energy storage efficiency. In this paper, an experimental and modeling investigation on the pressure drop inside the adsorption packed beds is performed. An accurate semi-analytical closed-form relationship is proposed to calculate the pressure drop inside a column of adsorbent materials, taking into account the Laplacian friction, as well as the inertial effects. The model covers a wide range of porosity, between low-permeability medium, a dense packed bed of spherical particles, and high-permeability media, a pure viscous fluid. A modified permeability is defined to consider the inertial effect for a moderate range of the particle Reynolds number (0 < Rep < 300). An experimental apparatus is designed for measuring the pressure drop for different bed sizes and inlet air velocities. The proposed model shows good agreement with the experimental data with the relative difference of 7.6% at 0.73 m/s for silica gel and 15.3% at 0.84 m/s for zeolite 4A packed beds. The experiment reveals that the effect of water uptake on the pressure drop of packed bed with wet adsorbent is negligible in the tested particle Reynolds number range, with a relative difference of less than 1.0% compared to dry adsorbent for 18–30 cm long columns. The proposed formula for pressure drop, consequently, can be applicable for wet adsorbents regardless of the water uptake amount, with a good level of accuracy. Moreover, the analytical model shows up to ±2% change in pressure drop due to heat of adsorption of the tested adsorber columns.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.applthermaleng.2018.03.098

Additional details

Identifiers

DOI
10.1016/j.applthermaleng.2018.03.098;
PII
S1359431117300194;

Publishing Information

Journal Title
Applied Thermal Engineering
Journal Volume
138
Journal Page Range
p. 731-739
ISSN
1359-4311
CODEN
ATENFT

Optional Information

Copyright
Copyright (c) 2018 Elsevier Ltd. All rights reserved.