Published October 15, 2017 | Version v1
Journal article

Development of high-temperature corrosion risk monitoring system in pulverized coal boilers based on reducing conditions identification and CFD simulations

Description

Highlights: •Corrosion risk monitoring system was demonstrated based on CO and O2 measurements. •Four global gas phase kinetic mechanisms were implemented into CFD. •Global mechanisms were compared with detailed one in a perfectly stirred reactor. •CFD predictions were compared with measurements received from the monitoring system. -- Abstract: Low-emission combustion (for example the use of low-NOx burners and air staging) contributes to formation of a reducing atmosphere in the furnace, that is accompanied by oxygen depletion and excess of CO in the vicinity (boundary layer) of waterwalls. Corrosion of boiler tubes is often caused by reducing atmosphere. O2 and CO measurement in the boundary layer of evaporators can be a good indicator of corrosion risk assessment. System based on the on-line measurement of the O2 and CO concentration in the boundary layer of the industrial scale boiler walls was described. To improve the functionality of the monitoring system Computational Fluid Dynamics may appear helpful. A validated CFD model capable of properly predicting the CO and O2 concentration in the vicinity of the combustion chamber walls may help to adjust the monitoring system during variable boiler operating conditions or different fuel properties without the necessity to repeat the measurements for new conditions. The scientific part of the current research is concentrated on volatiles combustion simulation with the emphasis on CO burnout. Four popular global mechanisms have been implemented into CFD code and their CO and O2 predictive capabilities are demonstrated. Additionally global mechanisms have been compared to detailed one in Perfectly Stirred Reactor model. It appears that the choice of global mechanism has significant influence on CO and O2 prediction. The measurements of the CO and O2 in the waterwalls boundary layer have been extracted from the monitoring system and compared to simulation results. One of the tested mechanisms demonstrated acceptable qualitative agreement with the measurement in terms of O2 predictions. The quantitative accuracy of CFD-based oxygen prediction in the boundary layer was described as moderate. CFD-based CO prediction was less satisfactory.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apenergy.2017.04.084

Additional details

Identifiers

DOI
10.1016/j.apenergy.2017.04.084;
PII
S0306-2619(17)30487-7;

Publishing Information

Journal Title
Applied Energy
Journal Volume
204
Journal Issue
Complete
Journal Page Range
p. 1124-1137
ISSN
0306-2619
CODEN
APENDX

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.